• 35kV Low Loss Prefabricated Compact Substation for Grid
35kV Low Loss Prefabricated Compact Substation for Grid
discuss personally
Model
YBW-35
Basic info
Brand POWERTECH
Model NO. 35kV Low Loss Prefabricated Compact Substation for Grid
Rated voltage 35kV
Series YBW-35/0.4-2000
Product Detail

Description

An AC metal-enclosed shift switch cabinet is a three-phase, 50Hz indoor metal-enclosed switching device designed for power plants and substation systems. It operates at a rated voltage of 35kV, with a maximum current capacity of 2000A and a voltage limit not exceeding 40.5kV. Suitable for single-bus or single-bus segmented configurations, it serves as a reliable distribution solution.

This switchgear complies with standards such as DL/T 404-91, IEC 298, and GB 3906, incorporating essential safety features to prevent operational errors. These include protections against incorrect circuit breaker operation, live insertion or withdrawal of trolleys, grounding line faults, live grounding, and accidental energization of isolated sections (commonly referred to as the "five protections").

Compact substations are ideal for diverse applications, including residential communities, urban public distribution networks, busy downtown areas, and temporary construction power supply. Their versatility allows selection based on specific load requirements and environmental conditions. Since their introduction, compact substations have seen rapid adoption, with widespread use in developed countries—where they account for a significant share of distribution systems. In China, modernization and urban grid upgrades are driving their increasing deployment.

These substations are commonly employed in high-rise buildings, luxury residences, parks, residential complexes, small to medium industrial plants, mining operations, oil fields, and temporary construction sites, providing efficient power distribution within electrical networks.

 Features

  • Complete Power Distribution System – Integrates transformation, distribution, transmission, measurement, compensation, control, protection and communication functions in one unit.
  • Standardized Components – Consists of high-voltage switchgear, distribution transformer, low-voltage distribution panel and protective enclosure.
  • Outdoor Application Design – Features anti-corrosion, waterproof and dustproof construction suitable for long-term outdoor operation.
  • Compact Structure – Three-section integrated design (high-voltage, transformer, low-voltage) with small footprint.
  • Installation Advantages – Offers flexible siting, reduced civil works, shorter construction period and lower overall cost compared to conventional substations.
  • Reliable Operation – High operational stability with comprehensive protection functions.
  • Aesthetic Appearance – Modern enclosed design with better visual appeal than traditional solutions.
  • Wide Application Range – Ideal for urban grid upgrades, residential communities, industrial parks, commercial centers, transportation facilities and temporary power supply needs.
  • Technical Compliance – Meets relevant industry standards for performance and safety requirements.
  • Maintenance Friendly – Modular design simplifies inspection and servicing procedures.

Parameter

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download